• Compatible with battery manufacturing
• 3 Port Pilot Operated Poppet (VP300).
• Port size: 1/8, 1/4.
• Body ported, Base mounted.
• Normally Closed or Normally Open (Changeable).
• Compatible with battery manufacturing
• 3 Port Pilot Operated Poppet (VP500).
• Port size: 3/8, 1/4.
• Body ported, Base mounted.
• Normally Closed or Normally Open (Changeable).
• Compatible with battery manufacturing
• 3 Port Pilot Operated Poppet (VP700).
• Port size: 3/8, 1/2.
• Body ported, Base mounted.
• Normally Closed or Normally Open (Changeable).
• Compatible with battery manufacturing
• 3 Port Direct Operated Poppet.
• Rubber Seal.
• Actuation: Direct operated 2 position single solenoid.
• Operating pressure range: 0 to 0.9 MPa.
• Compatible with food manufacturing.
• 3 Port Pilot Operated Poppet (VP300).
• Port size: 1/8, 1/4.
• Body ported, Base mounted.
• Normally Closed or Normally Open (Changeable).
• for Manifold Use
• 3 port solenoid valve, direct operated
• Valve width: 7mm
• Weight: 5g (single unit valve)
• Operation noise: 38dB(A) or less
• Power consumption: 0.35W (std), 0.1W (w/power saving circuit)
• Fluid: Air.
• Operating pressure range: -100 kPa to 0.7.
• Ambient and fluid temperature [°C]: -10 to 50 (No freezing).
• Coil rated voltage [DC]: 24, 12 V.
• Enclosure: IP67 (Based on IEC60529).
• Fluid: Air.
• Operating pressure range: -100 kPa to 0.7.
• Ambient and fluid temperature [°C]: -10 to 50 (No freezing).
• Coil rated voltage [DC]: 24, 12 V.
• Enclosure: IP67 (Based on IEC60529).
• Fluid: Air.
• Operating pressure range: -100 kPa to 0.7.
• Ambient and fluid temperature [°C]: -10 to 50 (No freezing).
• Coil rated voltage [DC]: 24, 12 V.
• Enclosure: IP67 (Based on IEC60529).
• Fluid: Air.
• Operating pressure range: -100 kPa to 0.7.
• Ambient and fluid temperature [°C]: -10 to 50 (No freezing).
• Coil rated voltage [DC]: 24, 12 V.
• Enclosure: IP67 (Based on IEC60529).
• Fluid: air Operating pressure range (MPa): 0.15 to 0.7 Ambient and fluid temperature (°C): -10 to 50 (no freezing) Maximum operating frequency (Hz): 10
• Operating pressure range (MPa): 0.15 to 0.7 Ambient and fluid temperature (°C): -10 to 50 (no freezing) Maximum operating frequency (Hz): 10
• Ambient and fluid temperature (°C): -10 to 50 (no freezing) Maximum operating frequency (Hz): 10
• Maximum operating frequency (Hz): 10
• Fluid: air Operating pressure range (MPa): 0.15 to 0.7 Ambient and fluid temperature (°C): -10 to 50 (no freezing) Maximum operating frequency (Hz): 5
• Operating pressure range (MPa): 0.15 to 0.7 Ambient and fluid temperature (°C): -10 to 50 (no freezing) Maximum operating frequency (Hz): 5
• Ambient and fluid temperature (°C): -10 to 50 (no freezing) Maximum operating frequency (Hz): 5
• Maximum operating frequency (Hz): 5
• Fluid: air Operating pressure range (MPa): 0.15 to 0.7 Ambient and fluid temperature (°C): -10 to 50 (no freezing) Maximum operating frequency (Hz): 5
• Operating pressure range (MPa): 0.15 to 0.7 Ambient and fluid temperature (°C): -10 to 50 (no freezing) Maximum operating frequency (Hz): 5
• Ambient and fluid temperature (°C): -10 to 50 (no freezing) Maximum operating frequency (Hz): 5
• Maximum operating frequency (Hz): 5
• Rated voltage: 24VDC or 12VDC
• Electrical entry is available with M-type plug connector with lead wire or without connector
• Available with or without light/surge suppressor
• Manual override is available with non-locking push type or locking slotted type
• Light Weight: 1.1kg.
• Large Flow Capacity: 1/Nl/min 12857.65
• Low Power Consumption.
• No lubrication required.
• Possible to use in vacuum or under low pressures.
• Changeable actuation: N.C., N.O. or External pilot.
• Can be used as a selector or divider valve (External pilot).
• Control isolation periods – Valve shifts from operating to isolation mode
• Prevent accidents caused by uncontrolled movements – Optional soft start-up function
• Choose the configuration that best suits you – Select from normally closed or normally open.
• Modular connection type for connecting to FRL units
• Saves space and reduces piping work
• Low power consumption: 0.35 W (Without light)
• Enclosure: IP65.
• Modular connection type for connecting to FRL units
• Saves space and reduces piping work
• Low power consumption: 0.35 W (Without light)
• Enclosure: IP65.
• Connect it to your FRL unit - Modular connection type
• Prevent accidents caused by uncontrolled movements - Optional soft start-up function
• Avoid pressure drops - A check valve is incorporated in the pilot flow path
• Stay safely connected – PROFIsafe or Functional Safety over EtherCAT® compatible.
• Wide variety of valve options .
• Low Power Consumption.
• Universal porting type.
• Same mounting dimensions as the current product in both types (body ported and for manifold type).
• Low concentration ozone resistant: HNBR rubber seal.
• RoHS and CE compliant.
• Direct operated, 3 port solenoid valve Max. system pressure (MPa): water, air, oil 2.0; steam 1.0 Reduction of power consumption (DC specification): VX31: 6W to 4.5W, VX32: 8W to 7W, VX33: 11.5W to 10.5W Enclosure equivalent to IP65 UL94V-0 conformed flame resistant mold coil material
• Max. system pressure (MPa): water, air, oil 2.0; steam 1.0 Reduction of power consumption (DC specification): VX31: 6W to 4.5W, VX32: 8W to 7W, VX33: 11.5W to 10.5W Enclosure equivalent to IP65 UL94V-0 conformed flame resistant mold coil material
• Reduction of power consumption (DC specification): VX31: 6W to 4.5W, VX32: 8W to 7W, VX33: 11.5W to 10.5W Enclosure equivalent to IP65 UL94V-0 conformed flame resistant mold coil material
• Enclosure equivalent to IP65 UL94V-0 conformed flame resistant mold coil material
• UL94V-0 conformed flame resistant mold coil material
• Compatible with battery manufacturing
• Fluid: Air.
• Operating pressure range: -100 kPa to 0.7.
• Ambient and fluid temperature [°C]: -10 to 50 (No freezing).
• Coil rated voltage [DC]: 24, 12 V.
• Enclosure: IP67 (Based on IEC60529).
• Compatible with battery manufacturing
• Fluid: Air.
• Operating pressure range: -100 kPa to 0.7.
• Ambient and fluid temperature [°C]: -10 to 50 (No freezing).
• Coil rated voltage [DC]: 24, 12 V.
• Enclosure: IP67 (Based on IEC60529).
• Compatible with battery manufacturing
• Fluid: Air.
• Operating pressure range: -100 kPa to 0.7.
• Ambient and fluid temperature [°C]: -10 to 50 (No freezing).
• Coil rated voltage [DC]: 24, 12 V.
• Enclosure: IP67 (Based on IEC60529).
• Utilisation of the standard SY5/7/9000 bodies.
• 52-SY when used with a safety barrier is certified and tested to the following ATEX classification: Ex II 2G EEx ia IIB T4..T6.
• Five kinds of safety barriers are available.
• Two types of plug connectors are available.
• The terminal box type (T) is IP65 compliant.
• Long life time (same as standard SY series).
• Body Ported.
• Utilisation of the standard SY5/7/9000 bodies.
• 52-SY when used with a safety barrier is certified and tested to the following ATEX classification: Ex II 2G EEx ia IIB T4..T6.
• Two kinds of safety barriers are available.
• Two types of plug connectors are available.
• The terminal box type (T) is IP65 compliant.
• Long life time (same as standard SY series).
• Base Mounted.
• ATEX
• Fluid: air/inert gas
• Operating pressure range: 0.1 - 0.7MPa (high pressure type 1.0MPa)
• mm²: metal seal 3,2; rubber seal 4,5
• Coil rated voltage: 24VDC
• Response time (ms) standard 1W: metal seal 20 or less; rubber seal 25 or less
• Ambient & fluid temperature: -10 to 50° C
• ATEX
• Fluid: air/inert gas
• Operating pressure range: 0.1 - 0.7MPa (high pressure type 1.0MPa)
• mm²: metal seal 10,9; rubber seal 14,5
• Coil rated voltage: 24VDC
• Response time (ms) standard 1W: metal seal 29 or less; rubber seal 34 or less
• Ambient & fluid temperature: -10 to 50° C
• Achieve fast actuator movements - Response time ON at 2.5 ms and OFF at 3 ms
• Use it in narrow places - Compact size of 91.5 x 16 x 34 mm
• Get great protection against water - IP67 enclosure.
• Achieve fast actuator movements - Response time ON at 2.5 ms and OFF at 3 ms
• Use it in narrow places - Compact size of 91.5 x 16 x 34 mm
• Get great protection against water - IP67 enclosure.
• Reduce cabling, wiring work and number of SI units – From 4 to 64 stations and 128 output points
• Get a wide range of communication capabilities – PROFINET®, EtherNet/IP™ and EtherCAT® protocols are available
• Save space in your application – Installation space reduced by up to 134 mm
• Keep centralised control management – Solenoid valves and electro-pneumatic regulators can be connected to the same manifold.