• Benefit from controlling 2 fluid channels with a single chiller
• Cut your costs – Triple inverter reduces power consumption by 30% (compared to a chiller without inverter)
• Fit it perfectly into the battery industry – Water-cooled refrigeration type
• Enjoy its great usability and visibility – Touch panel with numeric keypad, alerts for alarms & maintenance and temperature waveform displayed.
• Ease your cooling - 2 fluid channels can be controlled by one single thermo-chiller thus having smaller footprint & wiring
• Expand your range of applications - Water cooling options available, usable in secondary battery manufacturing
• Use it outdoors - Water splash-resistant, IPX4 compliant
• Cut your costs - Reduced power consumption, only one refrigerator, fan and pump. No heater needed.
• Space saving solution – benefit from controlling 2 fluid channels with a single chiller
• Peace of mind with F-gas compliance – R454C refrigerant used (GWP:146)
• Cut your costs – Triple inverter reduces power consumption by 30% (compared to a chiller without inverter)
• Fit it perfectly into the battery industry – Water-cooled refrigeration type.
• Save space – Mount multiple equipment units together in a rack
• Ease your control, service and maintenance – Filters and drainage accessible via front panel
• Facilitate installation – Built-in filters, flow sensors and bypass piping.
• Optimise the quality of your process – Great temperature stability, up to ±0.1 °C
• Get that smart solution that will give you proactive control – Remote control to manage any anomalies or incidents
• Adapt to a wide variety of applications – Cooling capacity from 1.1 kW up to 38 kW
• Ease your control and maintenance – Advanced control functions and improved maintenance performance.
• Optimise the quality of your process – Great temperature stability, up to ±0.1 °C
• Peace of mind with F-gas compliance – R454C refrigerant used (GWP:146)
• Get that smart solution that will give you proactive control – Remote control to manage any anomalies or incidents
• Expand your application range ‒ Useable in harsh environments, from -20 to + 45 ºC.
• Cooling capacity: 9.5 kW
• Temperature stability: ±0.1 °C
• Set temperature range: 5 to 40 °C
• Triple inverter
• With heating function and self-diagnosis.
• Cooling capacity: 11 kW
• Temperature stability: ±0.1 °C
• Set temperature range: 5 to 40 °C
• Triple inverter
• With heating function and self-diagnosis.
• Cooling capacity: 10.5 to 28 kW
• Temperature stability: ±0.1 °C
• Set temperature range: 5 to 35 °C
• Triple inverter
• With heating function and self-diagnosis.
• Cooling capacity: 10.5 to 28 kW
• Temperature stability: ±0.1 °C
• Set temperature range: 5 to 35 °C
• Triple inverter
• With heating function and self-diagnosis.
• Cooling capacity: 11.5 to 24 kW
• Temperature stability: ±0.1 °C
• Set temperature range: 5 to 35 °C
• Triple inverter
• With heating function and self-diagnosis.
• Cooling capacity: 11.5 to 24 kW
• Temperature stability: ±0.1 °C
• Set temperature range: 5 to 35 °C
• Triple inverter
• With heating function and self-diagnosis.
• Fit it in your semiconductor application – The most reliable chiller for it
• Achieve cost reductions – Energy savings of up to 65% thanks to the use of an inverter compressor and pump
• Minimise maintenance – The pump housing and heat exchanger are located inside the tank
• Maximise the performance of your machine – Great temperature stability ±0.1 °C and set temperature range from -20 to 90 °C.
• Fit it in your semiconductor application – The most reliable chiller for it
• Achieve cost reductions – Energy savings of up to 65% thanks to the use of an inverter compressor and pump
• Minimise maintenance – The pump housing and heat exchanger are located inside the tank
• Maximise the performance of your machine – Great temperature stability ±0.1 °C and set temperature range from -20 to 90 °C.
• Decrease administration time and costs – CO2 requires no import or usage quotas under the F-Gas Regulation
• Simplify transportation – CO2, unlike many traditional refrigerants, is not subject to international air transport restrictions
• Use it in the semiconductor industry – Compliant with the SEMI S2, S8, F47
• Reduce your costs – Compressor and pump inverter for energy-efficient performance.
• Fit it in your semiconductor application – The most reliable chiller for it
• Achieve cost reductions – Energy savings of up to 65% thanks to the use of an inverter compressor and pump
• Minimise maintenance – The pump housing and heat exchanger are located inside the tank
• Peace of mind with F-gas compliance – R454C refrigerant used (GWP:146).
• Decrease administration time and costs – CO2 refrigerant (GWP=1) requires no import or usage quotas under the F-Gas Regulation
• Non-flammable refrigerant allows for unrestricted transportation by air – CO2, unlike many alternative refrigerants, is non-flammable and not subject to air freight restrictions
• Cut your energy costs – Inverter adapts power consumption to the work load
• Optimise the quality of your process – Great temperature stability, up to ±0.1 °C.
• Don't get bothered by the upcoming F-Gas regulation − CO2 refrigerated thermo-chiller. GWP=1
• Simplify your shipping − CO2, unlike many traditional refrigerants, is not subject to international air transport restrictions
• Use it in the semiconductor industry − Compliant with the SEMI S2, S8, F47
• Ease your control and maintenance − Advanced control functions and improved maintenance performance.
• Cooling capacity: 1.7 kW to 4.5 kW
• Temperature stability: ±0.1 °C
• Set temperature range: 5 to 40 °C
• Protection of the electrical unit: IP54
• Metal panel
• With heating function and self-diagnosis.
• Peace of mind with F-gas compliance – R454C refrigerant used (GWP:146)
• Save space – Mount multiple equipment units together in a rack
• Ease your control, service and maintenance – Filters and drainage accessible via front panel
• Facilitate installation – Built-in filters, flow sensors and bypass piping.
• Obtain a quieter working environment – Its design with fewer moving parts makes it less prone to vibrate
• Save space and installation time – Mount multiple equipment units together in a rack
• Increase your productivity and maximise your machine performance – Great temperature stability
• Get that smart solution that will give you proactive control – Anticipate any changes.
•
• Cooling capacity: 140 to 320 W
• Temperature stability: ±0.01 °C to ±0.03 °C
• Set temperature range: 10 to 60 °C
• Learning control function
• With heating function and self-diagnosis.
• Cooling capacity: 230 to 600 W
• Temperature stability: ±0.01 °C to ±0.03 °C
• Set temperature range: 10 to 60 °C
• Learning control function
• With heating function and self-diagnosis.
• Make the most of your machine and/or desktop space – W130 x D150 x H210 mm size. 3.5 kg weight
• Increase your productivity and maximise your machine performance – Only 41s to lower temperature by 10 ºC
• Work in a quiet, low vibration environment – Low noise design, as low as 37 dBA
• Be environmentally friendly – Refrigerant-free design.