Over dit product

• Compatible with battery manufacturing • This product is being discontinued and will be replaced by PF2M7 series. Update details here . • Compact and light weight. • Digital 2 color indication. • Elbow piping can be used. • Integrated flow adjustment valve. • Several combinations are possible. • Different mounting methods are possible.

Specifications

Option
R (Bracket for w/o Flow Adjustment Valve)
Display
3-digit, 7-segment LED / 2-colour display (Red/Green) / Renewed cycle: 10 times/sec
Approvals
CE
Connector
W [Lead Wire w/Connector (2 m) + Rubber Cover]
Enclosure
IP40
Flow rate
1 - 50 l/min (Dry air, N2, Ar) / 1 - 25 l/min (CO2)
Linearity
Display accuracy: ±3%F.S. or less (Fluid: Dry air) / Analogue output accuracy: ±5%F.S. or less
Port Size
C6 (ø6 One-touch Fitting)
Hysteresis
Variable
Display unit
Real-time flow rate l/min, CFM x 10-2 /Accumulated flow l, ft3 x 10-1
Repeatability
±1%F.S. or less (Fluid: Dry air) / Analogue output accuracy: ±3%F.S. or less
Response time
1 s (50 ms, 0.5 s, 2 s can be selected)
Switch output
NPN or PNP open collector output
Proof pressure
1 MPa
Set flow range
1 - 52.5 l/min (Dry air, N2, Ar) / 1 - 26.2 l/min (CO2)
Applied voltage
28 VDC (at NPN output)
Flow Rate Range
50 [1 to 50 (25 for CO2) l/min]
Indicator light
OUT1: Illuminates when output is turned ON (Green) / OUT2: Illuminates when output is turned ON (Red)
Applicable fluid
Dry air, N2, Ar, CO2 (Air quality grade is ISO8573.1-1, 1.2 to 1.6.2.)
Impact resistance
490 m/s2 in X, Y, Z directions 3 times each
Withstand voltage
1000 VAC for 1 min. between external terminal and case
Flow display range
1 - 52.5 l/min (Dry air, N2, Ar) / 1 - 26.2 l/min (CO2)
Instruction Manual
With Instruction Manual
Unit Specification
M (Fixed SI Unit)
Current consumption
55 mA or less
External input time
Input 30 ms or more
External input type
No-voltage input (Reed or Solid state)
Maximum load current
80 mA
Minimum display unit
0.1 l/min
Power supply voltage
24 VDC ±10%
Rated pressure range
–70 kPa - 750 kPa
Vibration resistance
Without orifice: 10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller / With orifice: 10 to 150 Hz with a 1.5 mm amplitude or 19.6 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller
Insulation resistance
50 MΩ or more (at 500 VDC measured via Megohmmeter) between external terminal and case
Internal voltage drop
NPN output: 1 V or less (at 80 mA) / PNP output: 1.5 V or less (at 80 mA)
Output Specifications
B (2 PNP Outputs)
Accumulated flow range
Max. 999999 l
Piping Entry Direction
Straight
Analogue current output
4 - 20 mA
Calibration Certificate
None
Operating humidity range
Operating, Stored: 35 - 85%R.H. (with no condensation)
Pressure characteristics
±5%F.S. or less (based on 0.35 MPa)
Switch output protection
Short-circuit protection, Overcurrent protection
Maximum fluid temperature
50 °C
Minimum fluid temperature
0 °C (with no freezing and condensation)
Maximum operating pressure
750 kPa
Minimum operating pressure
–100 kPa
Maximum ambient temperature
Operating: 50 °C / Stored: 60°C
Minimum ambient temperature
Operating: 0 °C / Stored: –10 °C (with no freezing and condensation)
Temperature characteristics
±2%F.S. (15 - 35 °C) / ±5%F.S. (0 - 50 °C)
Accumulated volume per pulse
0.1 l/pulse
Analogue output response time
1.5 s or less (90% response)
Analogue current output - Load Impedance
50 - 600 Ω
Analogue voltage output - Output Impedance
1 - 5 V / 1 kΩ

Vergelijk uitvoeringen

Kies direct de uitvoering die bij jouw aansluiting past.

3 van 3 uitvoeringen

Filter uitvoeringen

€ 327,34 excl. VAT

excl. btw
Niet op voorraad bij SMCLevertijd: onbekend
Flow display range
0.2 - 10.5 l/min (Dry air, N2, Ar) / 0.2 - 5.2 l/min (CO2)
Flow rate
0.2 - 10 l/min (Dry air, N2, Ar) / 0.2 - 5 l/min (CO2)
Flow Rate Range
10 [0.2 to 10 (5 for CO2) l/min]
Minimum display unit
0.01 l/min
Output Specifications
F [1 PNP Outputs + Analogue (4 to 20 mA)]
Port Size
F01 (G1/8)
Set flow range
0.2 - 10.5 l/min (Dry air, N2, Ar) / 0.2 - 5.2 l/min (CO2)
Unit Specification
Unit Switching Function

Niet bestelbaar: levertijd onbekend.

€ 335,75 excl. VAT

excl. btw
Niet op voorraad bij SMCLevertijd: onbekend
Flow display range
1 - 52.5 l/min (Dry air, N2, Ar) / 1 - 26.2 l/min (CO2)
Flow rate
1 - 50 l/min (Dry air, N2, Ar) / 1 - 25 l/min (CO2)
Flow Rate Range
50 [1 to 50 (25 for CO2) l/min]
Minimum display unit
0.1 l/min
Output Specifications
B (2 PNP Outputs)
Port Size
C6 (ø6 One-touch Fitting)
Set flow range
1 - 52.5 l/min (Dry air, N2, Ar) / 1 - 26.2 l/min (CO2)
Unit Specification
M (Fixed SI Unit)

Niet bestelbaar: levertijd onbekend.

€ 339,16 excl. VAT

excl. btw
Niet op voorraad bij SMCLevertijd: onbekend
Flow display range
—
Flow rate
—
Flow Rate Range
—
Minimum display unit
—
Output Specifications
—
Port Size
—
Set flow range
—
Unit Specification
—

Niet bestelbaar: levertijd onbekend.