- Grease
- Grease Compatible with Low Dew Points
- Piping
- Rc1/2
- Display
- LCD
- Enclosure
- IP65
- Standards
- CE/UKCA marking, UL/CSA
- Vendor I D
- 131 (0 x 0083)
- Display unit
- l/min, cfm (ft3/min)
- I O- Link type
- Device
- Repeatability
- ±1 % F.S.
- Settling time
- 0.5 s or less within ±5 % F.S. of flow command (at standard pressure)
- Display colour
- Main screen: Red/Green, Sub screen: Orange
- Event function
- Yes
- Proof pressure
- 1.0 MPa
- Specifications
- 6 (Analogue Voltage Input/Output + IO-Link/Switch Output, w/Unit Selection Function, Flow Rate Zero)
- I O- Link version
- V1.1
- Indicator light
- Lights up when switch output is turned ON. OUT1: Orange
- Applicable fluid
- Air, Nitrogen
- Control accuracy
- ±5 % F.S
- Switch operation
- Normal output, Reversed output
- Fluid temperature
- 0 - 50 °C
- Number of screens
- 3-screen display (Main screen, Sub screen x 2)
- Pressure accuracy
- ±5 % F.S. (Reference value)
- Withstand voltage
- 1000 VAC for 1 min between terminals and housing
- Configuration file
- IODD file
- Current input type
- Current input: 4 to 20 mA
- Flow display range
- 25 - 525 l/min
- Minimum cycle time
- 5.5 ms
- Switch output mode
- Tolerance, Error output, Output OFF
- Switch output type
- Select from NPN or PNP open collector output
- Voltage input type
- Voltage-input: 0 to 5 V, 0 to 10 V selectable
- Communication speed
- COM2 (38.4 kbps)
- Current consumption
- 0.2 A or less
- Process data length
- Input Data: 8 bytes, Output Data: 2 bytes
- General power supply
- 24 VDC ±10 %
- Max. applied voltage
- 30 VDC
- Maximum load current
- 80 mA
- Minimum display unit
- 1 l/min
- Rated pressure range
- 0.000 - 1.000 MPa
- Analog current output
- Current output: 4 to 20 mA
- Analog voltage output
- Voltage-output: 1 to 5 V, 0 to 10 V selectable
- Data storage function
- Yes
- Electrical protection
- Power supply polarity protection
- Insulation resistance
- 50 MΩ or more (500 VDC measured via megohmmeter) between terminals and housing
- Internal voltage drop
- 1.5 V or less (at 80 mA load current)
- Display unit, pressure
- kPa, MPa, kgf/cm2, bar, psi
- Fluid contact material
- Aluminum alloy, POM, Stainless steel 304, Steel, Brass, Si, NBR, HNBR, FKM
- Set control flow range
- 25 - 525 l/min
- Current input impedance
- 50Ω or less
- Display range, pressure
- −50 - 1050 kPa
- Measured pressure range
- −0.050 - 1.050 MPa
- Rated Control Flow Rate
- 44 (50 to 500 l/min)
- Voltage input impedance
- 1 MΩ approx
- Number of display digits
- Main screen: 4 digits (7 segments) Sub screen (Left): 4 digits (some digits are 11 segments, 7 segments for others) Sub screen (Right): 5 digits (some digits are 11 segments, 7 segments for others
- Operating humidity range
- Operation, Storage: 35 to 85 % R.H. (No condensation)
- Operating pressure range
- 1.0 MPa or less
- Pressure characteristics
- ±5 % F.S. (Operating pressure range, reference pressure standard)
- Switch output Delay time
- 5 ms or less, variable from 0 to 60 s/0.01 s increments
- Display reference condition
- Select from Standard conditions or Normal conditions
- Operating temperature range
- Operating: 0 to 50 °C, Stored: −10 to 60 °C (No condensation)
- Temperature characteristics
- ±5 % F.S. (0 to 50 °C, 25 °C standard)
- On request data communication
- Yes
- Flow rate measurement accuracy
- ±3 % F.S.
- Minimum display unit, pressure
- 1 kPa
- Operating pressure range, load
- 0.1 to 0.6 MPa (100 % F.S. at flow rate)
- Rated measurement temperature range
- 0 - 50 °C
- Accuracy temperature characteristics
- ±10 % F.S. (Reference value)
- Switch output short circuit protection
- Over current protection
- Analogue current output - Load Impedance
- 50 - 600 Ω
- Analogue voltage output - Output Impedance
- 1 MΩ approx.
- Set-up setting control flow rate minimum unit
- 1 l/min