- Thread
- F [G(PF)]
- Weight
- 0.570 Kg
- Accessory
- C (L Bracket: KT-ITV-L2)
- Linearity
- ±1% or less (Full span)
- Hysteresis
- 1% or less (Full span)
- Sensitivity
- ±1% or less (Full span)
- Input Signal
- 3 (Voltage 0 to 10 VDC)
- Repeatability
- ±1% or less (Full span)
- Monitor Output
- 1 (Analogue Output 1 to 5 VDC)
- Applicable fluid
- Air, N2, O2, Ar
- Display accuracy
- ±2% or less (Full span) ±1 digit
- Set pressure range
- 0.01 to 3.0 MPa
- Current consumption
- 0.12 A or less
- Cable Connector Type
- N (Without Cable Connector)
- General power supply
- 24 VDC ±10%
- Max. supply pressure
- 5 MPa
- Min. supply pressure
- Whichever is higher: 0.5 MPa or the set pressure +0.2 MPa
- Minimum display unit
- MPa: 0.01, kgf/cm2: 0.1, bar: 0.1, psi: 1
- Pressure Display Unit
- MPa
- Output signal Analogue
- 1 to 5 VDC (Output impedance: Approximately 1 kΩ) Output accuracy within ±6% (Full span)
- Maximum fluid temperature
- 50°C
- Minimum fluid temperature
- 0°C
- Maximum ambient temperature
- 50°C
- Minimum ambient temperature
- 0°C
- Temperature characteristics
- ±0.12% or less (Full span)/°C
- Input impedance Voltage type
- 6 to 6.5 kΩ (at ordinary temperature)