- Bracket
- None
- Display
- LCD (Can be rotated 90, 180, and 270 degrees)
- Enclosure
- IP40
- Lead wire
- With lead wire with connector (3 m/5 core)
- Port Size
- C8 (8mm)
- Standards
- CE/UKCA
- Repeatability
- ±1 % F.S.
- Settling time
- Reaches within ±3 % F.S. of the commanded flow rate in 1 second or less (Under the reference conditions)
- Applicable fluid
- Dry air, N2, Ar, CO2 (JIS B 8392-1:2012 [1:6:2], ISO 8573-1:2010 [1:6:2])
- Control accuracy
- ±3 % F.S
- Switch operation
- Select from normal output or reversed output
- Max. load current
- 30 VDC
- Withstand voltage
- 1000 VAC for 1 min between terminals and housing
- Switch output mode
- Limit deviation tolerance mode, accumulated output, accumulated pulse output, error output, switch output off
- Switch output type
- Select from NPN or PNP open collector output
- Unit Specification
- M (SI Units Only)
- Withstand pressure
- 1 MPa
- Current consumption
- 200 mA or less
- Mounting orientation
- The display cannot be mounted with the screen facing down
- Power supply voltage
- 24 VDC ±10 %
- Electrical protection
- Power supply polarity protection
- Flow detection method
- Heating type sensor
- Insulation resistance
- 50 MΩ or more (500 VDC measured via megohmmeter) between terminals and housing
- Internal voltage drop
- 1.5 V or less (at 80 mA load current)
- Control command method
- IO-Link, analogue input, local setting
- Fluid contact material
- PPS, FKM, Stainless steel, Brass, PTFE, Si, Au, GE4F
- Set control flow range
- 0.5 - 50 l/min (Dry air, N2, Ar), 0.5 - 25 l/min (CO2)
- Current input impedance
- 250Ω or less
- State when de-energised
- Fully closed (Normally closed (N.C.))
- Voltage input impedance
- 1 MΩ approx
- Analogue output accuracy
- ±3 % F.S.
- Operating humidity range
- Operation, Storage: 35 to 85 % R.H. (No condensation)
- Operating pressure range
- 150 - 300 kPa
- Pressure characteristics
- ±2 % F.S. (reference operating pressure)
- Rated Control Flow Range
- 50 (0.5 to 50 l/min)
- Switch output Delay time
- 5 ms or less, variable from 0 to 60 s/0.01 s increments
- Input/ Output Specification
- 2 [IN: Analogue Input (4 to 20 mA), OUT1: IO-Link/NPN/PNP, OUT2: Analogue Output (4 to 20 mA)]
- Display reference condition
- Select from standard condition (STD) and normal condition (NOR)
- Operating temperature range
- Operating: 0 to 50 °C, Stored: 0 to 60 °C (No freezing or condensation)
- Temperature characteristics
- ±5 % F.S. (0 to 50 °C, Reference: 25 °C)
- Accumulated volume per pulse
- 1 L/pulse
- Accumulated value hold function
- Select from every 2 or 5 minutes
- Analogue current load impedance
- 50 - 600 Ω
- Set point range Accumulated flow
- 0 - 999999999 L
- Analogue voltage output impedance
- 1 MΩ approx.
- Minimum display unit Accumulated flow
- 1 L
- Switch output short circuit protection
- Switch output power supply polarity protection, over current protection
- Operation Manual/ Calibration Certificate
- Operation Manual
- Minimum operational differential pressure
- 150 kPa
- Set-up setting control flow rate minimum unit
- 0.1 l/min