- Bracket
- S (Bracket)
- Display
- None
- Enclosure
- IP40
- Standards
- CE, UKCA, RoHS
- Input mode
- Flow rate command signal
- Input/ Output
- A3 (IN1: Common for NPN and PNP / INA: Analogue 1 to 5 V / OUT1: PNP / OUTA: Analogue 1 to 5 V)
- Repeatability
- ±1 % F.S.
- Settling time
- 0.5 s or less
- Proof pressure
- 1.0 MPa
- Applicable fluid
- Dry air, N2 (The air quality grade is JIS B 8392-1 1.1.2 to 1.6.2 and ISO 8573-1 1.1.2 to 1.6.2)
- Control accuracy
- ±3 % F.S. (at an operating differential pressure of 0.3 MPa and temperature of 25 °C)
- External Leakage
- 10 cm3/min or less
- Switch operation
- Reversed output
- Switch input mode
- Valve fully open command
- Switch input type
- 1 point (Photo-coupler isolation)
- Withstand voltage
- 1000 VAC for 1 min between terminals and housing
- Power Supply Cable
- C (w/Power Supply Cable, 3 m)
- Switch output mode
- Error output
- Switch output type
- 1 point (NPN open collector, PNP open collector)
- Current consumption
- Main power supply: 0.5 A or less, Signal power supply: 0.05 A or less
- Max. applied voltage
- 30 VDC
- Maximum load current
- 80 mA
- Mounting orientation
- Downward orientation not allowed
- Power supply voltage
- Main power supply: 24 VDC ±10 %, Signal power supply: 24 VDC ±10 %
- Display L E D indicator
- 2 points (power supply, error)
- Electrical protection
- Power supply polarity protection
- Flow detection method
- Thermal type
- Insulation resistance
- 50 MΩ or more (500 VDC measured via megohmmeter) between terminals and housing
- Internal voltage drop
- 1.5 V or less (at load current of 80 mA)
- Control command method
- Analogue input
- Fluid contact material
- PPS, FKM, Stainless steel 303, Stainless steel 304, Stainless steel 316, Electroless nickel plating, Si, Au, GE4F, DLC
- Set control flow range
- 3 - 300 l/min
- Valve driving actuator
- Linear motor
- Current input impedance
- 250 Ω or less
- State when de-energised
- Closed (Normally closed)
- Voltage input impedance
- Approx. 1 MΩ
- Operating humidity range
- Operating/Stored: 35 to 85 % RH (No condensation)
- Operating pressure range
- 50 - 800 kPa
- Pressure characteristics
- ±2 % F.S. (Standard operating differential pressure basis)
- Switch output Delay time
- 5 ms or less
- Operating temperature range
- Operating: 5 to 45 °C (Accuracy guarantee: 15 to 35 °C) Stored: −10 to 60 °C (No freezing and condensation)
- Temperature characteristics
- ±2 % F.S. (15 to 35 °C, 25 °C standard) ±5 % F.S. (0 to 50 °C, 25 °C standard)
- Flow rate display output mode
- For connection with the digital flow monitor PFG310
- Flow rate display output type
- 4 - 20 mA
- Analogue current load impedance
- 50 - 600 Ω
- Switch input internal resistance
- 5 kΩ
- Analogue voltage output impedance
- Approx. 1 kΩ
- Switch output short circuit protection
- Switch output polarity protection, Over current protection
- Flow rate display output load impedance
- 50 - 600 Ω
- Operational differential pressure range
- 50 - 500 kPa
- Standard operational differential pressure
- 300 kPa