Voor 15.00 uur besteld, morgen bezorgd indien op voorraad · Deskundig advies van HZIndustrial
HZ Industrial
HZIndustrialIndustrial webshop
← Back to catalogue
Digitale Flowsensor

Sensors & Switches > Flow Sensors

Digitale Flowsensor

SKU: PFM750-C6-E

Kies uitvoering

41 opties

Selecteer de aansluiting die je nodig hebt.

Price

€ 232,70 excl. VAT

VAT
21%
SMC stock
56 at SMC

Over dit product

• This product is being discontinued and will be replaced by PF2M7 series. Update details here . • Compact and light weight. • Digital 2 color indication. • Elbow piping can be used. • Integrated flow adjustment valve. • Several combinations are possible. • Different mounting methods are possible.

Specifications

Option
None
Weight
0.250 Kg
Display
3-digit, 7-segment LED / 2-colour display (Red/Green) / Renewed cycle: 10 times/sec
Approvals
CE
Connector
Lead Wire w/Connector (2 m)
Enclosure
IP40
Flow rate
1 - 50 l/min (Dry air, N2, Ar) / 1 - 25 l/min (CO2)
Linearity
Display accuracy: ±3%F.S. or less (Fluid: Dry air) / Analogue output accuracy: ±5%F.S. or less
Port Size
C6 (ø6 One-touch Fitting)
Hysteresis
Variable
Display unit
Real-time flow rate l/min, CFM x 10-2 /Accumulated flow l, ft3 x 10-1
Made to Order
None
Repeatability
±1%F.S. or less (Fluid: Dry air) / Analogue output accuracy: ±3%F.S. or less
Response time
1 s (50 ms, 0.5 s, 2 s can be selected)
Switch output
NPN or PNP open collector output
Proof pressure
1 MPa
Set flow range
1 - 52.5 l/min (Dry air, N2, Ar) / 1 - 26.2 l/min (CO2)
Applied voltage
28 VDC (at NPN output)
Flow Rate Range
50 [1 to 50 (25 for CO2) l/min]
Indicator light
OUT1: Illuminates when output is turned ON (Green) / OUT2: Illuminates when output is turned ON (Red)
Applicable fluid
Dry air, N2, Ar, CO2 (Air quality grade is ISO8573.1-1, 1.2 to 1.6.2.)
Impact resistance
490 m/s2 in X, Y, Z directions 3 times each
Withstand voltage
1000 VAC for 1 min. between external terminal and case
Flow display range
1 - 52.5 l/min (Dry air, N2, Ar) / 1 - 26.2 l/min (CO2)
Instruction Manual
With Instruction Manual
Unit Specification
Unit Switching Function
Current consumption
55 mA or less
External input time
Input 30 ms or more
External input type
No-voltage input (Reed or Solid state)
Maximum load current
80 mA
Minimum display unit
0.1 l/min
Power supply voltage
24 VDC ±10%
Rated pressure range
–70 kPa - 750 kPa
Vibration resistance
Without orifice: 10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller / With orifice: 10 to 150 Hz with a 1.5 mm amplitude or 19.6 m/s2 acceleration, in each X, Y, Z direction for 2 hrs, whichever is smaller
Flow Adjustment Valve
None
Insulation resistance
50 MΩ or more (at 500 VDC measured via Megohmmeter) between external terminal and case
Internal voltage drop
NPN output: 1 V or less (at 80 mA) / PNP output: 1.5 V or less (at 80 mA)
Output Specifications
E [1 PNP Outputs + Analogue (1 to 5 V)]
Accumulated flow range
Max. 999999 l
Piping Entry Direction
Straight
Analogue current output
4 - 20 mA
Calibration Certificate
None
Operating humidity range
Operating, Stored: 35 - 85%R.H. (with no condensation)
Pressure characteristics
±5%F.S. or less (based on 0.35 MPa)
Switch output protection
Short-circuit protection, Overcurrent protection
Maximum fluid temperature
50 °C
Minimum fluid temperature
0 °C (with no freezing and condensation)
Maximum operating pressure
750 kPa
Minimum operating pressure
–100 kPa
Maximum ambient temperature
Operating: 50 °C / Stored: 60°C
Minimum ambient temperature
Operating: 0 °C / Stored: –10 °C (with no freezing and condensation)
Temperature characteristics
±2%F.S. (15 - 35 °C) / ±5%F.S. (0 - 50 °C)
Accumulated volume per pulse
0.1 l/pulse
Analogue output response time
1.5 s or less (90% response)
Analogue current output - Load Impedance
50 - 600 Ω
Analogue voltage output - Output Impedance
1 - 5 V / 1 kΩ

Documentatie

Operation manuals

Installation manuals

Vergelijk uitvoeringen

Kies direct de uitvoering die bij jouw aansluiting past.

41 van 41 uitvoeringen

Filter uitvoeringen

€ 230,36 excl. VAT

excl. btw
Niet op voorraad bij SMCLevertijd: onbekend
Accumulated volume per pulse
0.1 L/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
0.2 - 10.5 l/min (Dry air, N2, Ar) / 0.2 - 5.2 l/min (CO2)
Flow rate
0.2 - 10 l/min (Dry air, N2, Ar) / 0.2 - 5 l/min (CO2)
Flow Rate Range
10 [0.2 to 10 (5 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.01 l/min
Output Specification
—

Niet bestelbaar: levertijd onbekend.

€ 230,36 excl. VAT

excl. btw
32 stuks bij SMC
Accumulated volume per pulse
0.1 L/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
0.2 - 10.5 l/min (Dry air, N2, Ar) / 0.2 - 5.2 l/min (CO2)
Flow rate
0.2 - 10 l/min (Dry air, N2, Ar) / 0.2 - 5 l/min (CO2)
Flow Rate Range
10 [0.2 to 10 (5 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.01 l/min
Output Specification
—

€ 233,85 excl. VAT

excl. btw
Niet op voorraad bij SMCLevertijd: onbekend
Accumulated volume per pulse
0.1 L/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
0.2 - 10.5 l/min (Dry air, N2, Ar) / 0.2 - 5.2 l/min (CO2)
Flow rate
0.2 - 10 l/min (Dry air, N2, Ar) / 0.2 - 5 l/min (CO2)
Flow Rate Range
10 [0.2 to 10 (5 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.01 l/min
Output Specification
—

Niet bestelbaar: levertijd onbekend.

€ 232,76 excl. VAT

excl. btw
Niet op voorraad bij SMCLevertijd: onbekend
Accumulated volume per pulse
0.1 L/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
0.2 - 10.5 l/min (Dry air, N2, Ar) / 0.2 - 5.2 l/min (CO2)
Flow rate
0.2 - 10 l/min (Dry air, N2, Ar) / 0.2 - 5 l/min (CO2)
Flow Rate Range
10 [0.2 to 10 (5 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.01 l/min
Output Specification
—

Niet bestelbaar: levertijd onbekend.

€ 232,76 excl. VAT

excl. btw
Niet op voorraad bij SMCLevertijd: onbekend
Accumulated volume per pulse
0.1 L/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
0.2 - 10.5 l/min (Dry air, N2, Ar) / 0.2 - 5.2 l/min (CO2)
Flow rate
0.2 - 10 l/min (Dry air, N2, Ar) / 0.2 - 5 l/min (CO2)
Flow Rate Range
10 [0.2 to 10 (5 for CO2) l/min]
Instruction Manual
N (None)
Minimum display unit
0.01 l/min
Output Specification
—

Niet bestelbaar: levertijd onbekend.

€ 236,13 excl. VAT

excl. btw
12 stuks bij SMC
Accumulated volume per pulse
0.1 L/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
0.2 - 10.5 l/min (Dry air, N2, Ar) / 0.2 - 5.2 l/min (CO2)
Flow rate
0.2 - 10 l/min (Dry air, N2, Ar) / 0.2 - 5 l/min (CO2)
Flow Rate Range
10 [0.2 to 10 (5 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.01 l/min
Output Specification
—

€ 253,18 excl. VAT

excl. btw
76 stuks bij SMC
Accumulated volume per pulse
0.1 L/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
0.2 - 10.5 l/min (Dry air, N2, Ar) / 0.2 - 5.2 l/min (CO2)
Flow rate
0.2 - 10 l/min (Dry air, N2, Ar) / 0.2 - 5 l/min (CO2)
Flow Rate Range
10 [0.2 to 10 (5 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.01 l/min
Output Specification
—

€ 253,28 excl. VAT

excl. btw
20 stuks bij SMC
Accumulated volume per pulse
0.1 L/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
0.2 - 10.5 l/min (Dry air, N2, Ar) / 0.2 - 5.2 l/min (CO2)
Flow rate
0.2 - 10 l/min (Dry air, N2, Ar) / 0.2 - 5 l/min (CO2)
Flow Rate Range
10 [0.2 to 10 (5 for CO2) ℓ/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.01 l/min
Output Specification
B (2 PNP Outputs)

€ 268,25 excl. VAT

excl. btw
29 stuks bij SMC
Accumulated volume per pulse
0.1 L/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
0.2 - 10.5 l/min (Dry air, N2, Ar) / 0.2 - 5.2 l/min (CO2)
Flow rate
0.2 - 10 l/min (Dry air, N2, Ar) / 0.2 - 5 l/min (CO2)
Flow Rate Range
10 [0.2 to 10 (5 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.01 l/min
Output Specification
—

€ 253,28 excl. VAT

excl. btw
25 stuks bij SMC
Accumulated volume per pulse
0.1 L/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
0.2 - 10.5 l/min (Dry air, N2, Ar) / 0.2 - 5.2 l/min (CO2)
Flow rate
0.2 - 10 l/min (Dry air, N2, Ar) / 0.2 - 5 l/min (CO2)
Flow Rate Range
10 [0.2 to 10 (5 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.01 l/min
Output Specification
—

€ 258,87 excl. VAT

excl. btw
30 stuks bij SMC
Accumulated volume per pulse
0.1 L/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
0.2 - 10.5 l/min (Dry air, N2, Ar) / 0.2 - 5.2 l/min (CO2)
Flow rate
0.2 - 10 l/min (Dry air, N2, Ar) / 0.2 - 5 l/min (CO2)
Flow Rate Range
10 [0.2 to 10 (5 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.01 l/min
Output Specification
—

€ 236,18 excl. VAT

excl. btw
16 stuks bij SMC
Accumulated volume per pulse
1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
2 - 105 l/min (Dry air, N2, Ar) / 2 - 52 l/min (CO2)
Flow rate
2 - 100 l/min (Dry air, N2, Ar) / 2 - 50 l/min (CO2)
Flow Rate Range
11 [2 to 100 (50 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

€ 245,26 excl. VAT

excl. btw
161 stuks bij SMC
Accumulated volume per pulse
1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
2 - 105 l/min (Dry air, N2, Ar) / 2 - 52 l/min (CO2)
Flow rate
2 - 100 l/min (Dry air, N2, Ar) / 2 - 50 l/min (CO2)
Flow Rate Range
11 [2 to 100 (50 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

€ 230,36 excl. VAT

excl. btw
72 stuks bij SMC
Accumulated volume per pulse
1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
2 - 105 l/min (Dry air, N2, Ar) / 2 - 52 l/min (CO2)
Flow rate
2 - 100 l/min (Dry air, N2, Ar) / 2 - 50 l/min (CO2)
Flow Rate Range
11 [2 to 100 (50 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

€ 232,76 excl. VAT

excl. btw
22 stuks bij SMC
Accumulated volume per pulse
1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
2 - 105 l/min (Dry air, N2, Ar) / 2 - 52 l/min (CO2)
Flow rate
2 - 100 l/min (Dry air, N2, Ar) / 2 - 50 l/min (CO2)
Flow Rate Range
11 [2 to 100 (50 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

€ 230,36 excl. VAT

excl. btw
17 stuks bij SMC
Accumulated volume per pulse
1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
2 - 105 l/min (Dry air, N2, Ar) / 2 - 52 l/min (CO2)
Flow rate
2 - 100 l/min (Dry air, N2, Ar) / 2 - 50 l/min (CO2)
Flow Rate Range
11 [2 to 100 (50 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

€ 236,18 excl. VAT

excl. btw
6 stuks bij SMC
Accumulated volume per pulse
1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
2 - 105 l/min (Dry air, N2, Ar) / 2 - 52 l/min (CO2)
Flow rate
2 - 100 l/min (Dry air, N2, Ar) / 2 - 50 l/min (CO2)
Flow Rate Range
11 [2 to 100 (50 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

€ 230,25 excl. VAT

excl. btw
33 stuks bij SMC
Accumulated volume per pulse
1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
2 - 105 l/min (Dry air, N2, Ar) / 2 - 52 l/min (CO2)
Flow rate
2 - 100 l/min (Dry air, N2, Ar) / 2 - 50 l/min (CO2)
Flow Rate Range
11 [2 to 100 (50 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

€ 232,70 excl. VAT

excl. btw
50 stuks bij SMC
Accumulated volume per pulse
1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
2 - 105 l/min (Dry air, N2, Ar) / 2 - 52 l/min (CO2)
Flow rate
2 - 100 l/min (Dry air, N2, Ar) / 2 - 50 l/min (CO2)
Flow Rate Range
11 [2 to 100 (50 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

€ 235,95 excl. VAT

excl. btw
29 stuks bij SMC
Accumulated volume per pulse
1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
2 - 105 l/min (Dry air, N2, Ar) / 2 - 52 l/min (CO2)
Flow rate
2 - 100 l/min (Dry air, N2, Ar) / 2 - 50 l/min (CO2)
Flow Rate Range
11 [2 to 100 (50 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

€ 244,82 excl. VAT

excl. btw
6 stuks bij SMC
Accumulated volume per pulse
1 l/pulse
Connector
W [Lead Wire w/Connector (2 m) + Rubber Cover]
Flow display range
2 - 105 l/min (Dry air, N2, Ar) / 2 - 52 l/min (CO2)
Flow rate
2 - 100 l/min (Dry air, N2, Ar) / 2 - 50 l/min (CO2)
Flow Rate Range
11 [2 to 100 (50 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

€ 253,22 excl. VAT

excl. btw
100 stuks bij SMC
Accumulated volume per pulse
1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
2 - 105 l/min (Dry air, N2, Ar) / 2 - 52 l/min (CO2)
Flow rate
2 - 100 l/min (Dry air, N2, Ar) / 2 - 50 l/min (CO2)
Flow Rate Range
11 [2 to 100 (50 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

€ 255,49 excl. VAT

excl. btw
12 stuks bij SMC
Accumulated volume per pulse
1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
2 - 105 l/min (Dry air, N2, Ar) / 2 - 52 l/min (CO2)
Flow rate
2 - 100 l/min (Dry air, N2, Ar) / 2 - 50 l/min (CO2)
Flow Rate Range
11 [2 to 100 (50 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

€ 253,23 excl. VAT

excl. btw
36 stuks bij SMC
Accumulated volume per pulse
1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
2 - 105 l/min (Dry air, N2, Ar) / 2 - 52 l/min (CO2)
Flow rate
2 - 100 l/min (Dry air, N2, Ar) / 2 - 50 l/min (CO2)
Flow Rate Range
11 [2 to 100 (50 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

€ 258,87 excl. VAT

excl. btw
Niet op voorraad bij SMCLevertijd: onbekend
Accumulated volume per pulse
1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
2 - 105 l/min (Dry air, N2, Ar) / 2 - 52 l/min (CO2)
Flow rate
2 - 100 l/min (Dry air, N2, Ar) / 2 - 50 l/min (CO2)
Flow Rate Range
11 [2 to 100 (50 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

Niet bestelbaar: levertijd onbekend.

€ 230,36 excl. VAT

excl. btw
23 stuks bij SMC
Accumulated volume per pulse
0.1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
0.5 - 26.3 l/min (Dry air, N2, Ar) / 0.5 - 13.1 l/min (CO2)
Flow rate
0.5 - 25 l/min (Dry air, N2, Ar) / 0.5 - 12.5 l/min (CO2)
Flow Rate Range
25 [0.5 to 25 (12.5 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

€ 236,18 excl. VAT

excl. btw
64 stuks bij SMC
Accumulated volume per pulse
0.1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
0.5 - 26.3 l/min (Dry air, N2, Ar) / 0.5 - 13.1 l/min (CO2)
Flow rate
0.5 - 25 l/min (Dry air, N2, Ar) / 0.5 - 12.5 l/min (CO2)
Flow Rate Range
25 [0.5 to 25 (12.5 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

€ 236,12 excl. VAT

excl. btw
Niet op voorraad bij SMCLevertijd: onbekend
Accumulated volume per pulse
0.1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
0.5 - 26.3 l/min (Dry air, N2, Ar) / 0.5 - 13.1 l/min (CO2)
Flow rate
0.5 - 25 l/min (Dry air, N2, Ar) / 0.5 - 12.5 l/min (CO2)
Flow Rate Range
25 [0.5 to 25 (12.5 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

Niet bestelbaar: levertijd onbekend.

€ 253,22 excl. VAT

excl. btw
8 stuks bij SMC
Accumulated volume per pulse
0.1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
0.5 - 26.3 l/min (Dry air, N2, Ar) / 0.5 - 13.1 l/min (CO2)
Flow rate
0.5 - 25 l/min (Dry air, N2, Ar) / 0.5 - 12.5 l/min (CO2)
Flow Rate Range
25 [0.5 to 25 (12.5 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

€ 258,87 excl. VAT

excl. btw
Niet op voorraad bij SMCLevertijd: onbekend
Accumulated volume per pulse
0.1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
0.5 - 26.3 l/min (Dry air, N2, Ar) / 0.5 - 13.1 l/min (CO2)
Flow rate
0.5 - 25 l/min (Dry air, N2, Ar) / 0.5 - 12.5 l/min (CO2)
Flow Rate Range
25 [0.5 to 25 (12.5 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

Niet bestelbaar: levertijd onbekend.

€ 263,91 excl. VAT

excl. btw
Niet op voorraad bij SMCLevertijd: onbekend
Accumulated volume per pulse
0.1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
0.5 - 26.3 l/min (Dry air, N2, Ar) / 0.5 - 13.1 l/min (CO2)
Flow rate
0.5 - 25 l/min (Dry air, N2, Ar) / 0.5 - 12.5 l/min (CO2)
Flow Rate Range
25 [0.5 to 25 (12.5 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

Niet bestelbaar: levertijd onbekend.

€ 245,26 excl. VAT

excl. btw
90 stuks bij SMC
Accumulated volume per pulse
0.1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
1 - 52.5 l/min (Dry air, N2, Ar) / 1 - 26.2 l/min (CO2)
Flow rate
1 - 50 l/min (Dry air, N2, Ar) / 1 - 25 l/min (CO2)
Flow Rate Range
50 [1 to 50 (25 for CO2) ℓ/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
F [1 PNP Outputs + Analog (4 to 20 mA)]

€ 232,70 excl. VAT

excl. btw
56 stuks bij SMC
Accumulated volume per pulse
0.1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
1 - 52.5 l/min (Dry air, N2, Ar) / 1 - 26.2 l/min (CO2)
Flow rate
1 - 50 l/min (Dry air, N2, Ar) / 1 - 25 l/min (CO2)
Flow Rate Range
50 [1 to 50 (25 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

€ 232,76 excl. VAT

excl. btw
Niet op voorraad bij SMCLevertijd: onbekend
Accumulated volume per pulse
0.1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
1 - 52.5 l/min (Dry air, N2, Ar) / 1 - 26.2 l/min (CO2)
Flow rate
1 - 50 l/min (Dry air, N2, Ar) / 1 - 25 l/min (CO2)
Flow Rate Range
50 [1 to 50 (25 for CO2) l/min]
Instruction Manual
N (None)
Minimum display unit
0.1 l/min
Output Specification
—

Niet bestelbaar: levertijd onbekend.

€ 236,13 excl. VAT

excl. btw
38 stuks bij SMC
Accumulated volume per pulse
0.1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
1 - 52.5 l/min (Dry air, N2, Ar) / 1 - 26.2 l/min (CO2)
Flow rate
1 - 50 l/min (Dry air, N2, Ar) / 1 - 25 l/min (CO2)
Flow Rate Range
50 [1 to 50 (25 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

€ 232,63 excl. VAT

excl. btw
40 stuks bij SMC
Accumulated volume per pulse
0.1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
1 - 52.5 l/min (Dry air, N2, Ar) / 1 - 26.2 l/min (CO2)
Flow rate
1 - 50 l/min (Dry air, N2, Ar) / 1 - 25 l/min (CO2)
Flow Rate Range
50 [1 to 50 (25 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

€ 236,00 excl. VAT

excl. btw
144 stuks bij SMC
Accumulated volume per pulse
0.1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
1 - 52.5 l/min (Dry air, N2, Ar) / 1 - 26.2 l/min (CO2)
Flow rate
1 - 50 l/min (Dry air, N2, Ar) / 1 - 25 l/min (CO2)
Flow Rate Range
50 [1 to 50 (25 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

€ 255,62 excl. VAT

excl. btw
11 stuks bij SMC
Accumulated volume per pulse
0.1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
1 - 52.5 l/min (Dry air, N2, Ar) / 1 - 26.2 l/min (CO2)
Flow rate
1 - 50 l/min (Dry air, N2, Ar) / 1 - 25 l/min (CO2)
Flow Rate Range
50 [1 to 50 (25 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

€ 259,05 excl. VAT

excl. btw
4 stuks bij SMC
Accumulated volume per pulse
0.1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
1 - 52.5 l/min (Dry air, N2, Ar) / 1 - 26.2 l/min (CO2)
Flow rate
1 - 50 l/min (Dry air, N2, Ar) / 1 - 25 l/min (CO2)
Flow Rate Range
50 [1 to 50 (25 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

€ 253,23 excl. VAT

excl. btw
20 stuks bij SMC
Accumulated volume per pulse
0.1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
1 - 52.5 l/min (Dry air, N2, Ar) / 1 - 26.2 l/min (CO2)
Flow rate
1 - 50 l/min (Dry air, N2, Ar) / 1 - 25 l/min (CO2)
Flow Rate Range
50 [1 to 50 (25 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—

€ 259,05 excl. VAT

excl. btw
50 stuks bij SMC
Accumulated volume per pulse
0.1 l/pulse
Connector
Lead Wire w/Connector (2 m)
Flow display range
1 - 52.5 l/min (Dry air, N2, Ar) / 1 - 26.2 l/min (CO2)
Flow rate
1 - 50 l/min (Dry air, N2, Ar) / 1 - 25 l/min (CO2)
Flow Rate Range
50 [1 to 50 (25 for CO2) l/min]
Instruction Manual
With Instruction Manual
Minimum display unit
0.1 l/min
Output Specification
—