- Weight
- 0.490 Kg
- Display
- LCD, 2-screen display (Main screen/Sub screen) Main screen: Red/Green, Sub screen: Orange Main screen: 5 digits, 7 segment, Sub screen: 6 digits, 7 segment
- Approvals
- CE, EMC, RoHS
- Enclosure
- IP65
- Impedance
- Maximum load impedance: Approx. 600 Ω
- Lead Wire
- N (w/o Lead Wire and M12 Connector)
- Hysteresis
- Variable from 0
- Output mode
- Select from Instantaneous output (Hysteresis mode or Window comparator mode), Accumulated output, or Accumulated pulse output
- Repeatability
- ±1.0% F.S.
- Flow Direction
- Left to Right
- Proof pressure
- 1.5 MPa
- Indicator light
- OUT indicator: Red LED is ON when output is ON
- Applicable fluid
- Air, Nitrogen
- Display accuracy
- ±3.0 % F.S.
- Rated Flow Range
- 02 (20 to 2000 l/min)
- Switch operation
- Select from Normal or Reversed output
- Max. load current
- 80 mA
- Withstand voltage
- 1000 VAC for 1 minute between terminals and housing
- Unit Specification
- Unit Selection Function
- Current consumption
- 150 mA or less
- External input mode
- Select from Accumulated value external reset or Peak/Bottom value reset
- External input time
- 30 ms or longer
- External input type
- No-voltage input: 0.4 V or less
- Analogue output type
- Current output: 4 to 20 mA
- General power supply
- 24 VDC ±10 %
- Max. applied voltage
- 28 VDC
- Minimum display unit
- 2 l/min
- Rated pressure range
- 0 - 1 MPa
- Electrical protection
- Polarity protection
- Flow detection method
- Thermal type
- Insulation resistance
- 50 MΩ (500 VDC measured via megohmmeter) between terminals and housing
- Internal voltage drop
- NPN output type: 1 V or less (at load current of 80 mA)
- Output Specifications
- DS (Out: NPN; Func: Analogue Current Output <-> External Input)
- Calibration Certificate
- None, Certificate in both English and Japanese
- Analogue output accuracy
- ±3.0 % F.S.
- Operating humidity range
- Operating/Stored: 35 to 85 % RH (No condensation)
- Pressure characteristics
- ±5.0% F.S. (0 to 1.0 MPa, 0.5 MPa standard)
- Switch output protection
- Over current protection
- Maximum fluid temperature
- 50 °C
- Minimum fluid temperature
- 0 °C
- Operating temperature range
- Operating: 0 to 50 °C, Stored: -10 to 60 °C (No freezing or condensation)
- Smallest settable increment
- 2 l/min
- Switch output response time
- Select from 1 s, 2 s, or 5 s
- Accumulated volume per pulse
- 10 L/pulse
- Display range Accumulated flow
- 0 to 999,999,999,990 L
- Accumulated value hold function
- Interval of 2 or 5 minutes can be selected
- Set point range Instantaneous flow
- 20 - 2000 l/min
- Accuracy temperature characteristics
- ±5.0 % F.S. (Ambient temperature of 0 to 50 °C, 25 °C standard)
- Minimum display unit Accumulated flow
- 10 L
- Conform to the European Ro H S Directive
- Conform
- Contact material for circulating fluid
- Stainless steel 304, Aluminum alloy, PPS, HNBR [Sensor: Pt, Au, Ni, Fe, Lead glass (exempted from the RoHS application), Al2O3]
- Smallest settable increment Accumulated flow
- 10 L