- Weight
- 0.490 Kg
- Display
- LCD, 4-screen display Upper line: Red/Green, Lower line: Orange Upper/Lower line: 10 digits (7 segments 5 digits, 11 segments 5 digits)
- Approvals
- CE, EMC, RoHS
- Enclosure
- IP65
- Lead Wire
- w/Lead Wire and M12 Connector, 3 m
- Hysteresis
- Variable from 0
- Output mode
- Hysteresis mode, Window comparator mode, Error output, Output OFF, Accumulated output, Accumulated pulse output (Only flow rate)
- Repeatability
- ±1.0% F.S.
- Switch output
- Select from NPN or PNP open collector output
- Flow Direction
- Left to Right
- Proof pressure
- 1.5 MPa
- Indicator light
- OUT indicator: Orange LED is ON when output is ON
- Applicable fluid
- Air, Nitrogen
- Display accuracy
- ±3.0 % F.S.
- Rated Flow Range
- 02 (20 to 2000 l/min)
- Switch operation
- Select from Normal or Reversed output
- Max. load current
- 80 mA
- Withstand voltage
- 1000 VAC for 1 minute between terminals and housing
- Flow display range
- 0 to 2100 l/min (Flow under 20 L/min is displayed as “0”)
- Unit Specification
- Unit Selection Function
- Current consumption
- 150 mA or less
- Minimum display unit
- 2 l/min
- Output Specification
- L2 [Out1: IO-Link, Switch Output (N/P); Out2: Switch Output (N/P)]
- Rated pressure range
- 0 - 1 MPa
- Electrical protection
- Polarity protection
- Flow detection method
- Thermal type (Bypass flow type)
- Insulation resistance
- 50 MΩ (500 VDC measured via megohmmeter) between terminals and housing
- Calibration Certificate
- None, Certificate in both English and Japanese
- Operating humidity range
- Operating/Stored: 35 to 85 % RH (No condensation)
- Pressure characteristics
- ±5.0 % F.S. (Ambient temperature of 0 to 50 °C, 25 °C standard)
- Switch output protection
- Over current protection
- Maximum fluid temperature
- 50 °C
- Minimum fluid temperature
- 0 °C
- Operating temperature range
- Operating: 0 to 50 °C, Stored: -10 to 60 °C (No freezing or condensation)
- Smallest settable increment
- 2 l/min
- Switch output response time
- 5 ms or less
- Accumulated volume per pulse
- Select from 10 L/pulse or 100 L/pulse
- Display range Accumulated flow
- 0 to 9,999.99 x 106 L (6-digit display) 0 to 9,999,999.99 x 103 L (9-digit display)
- Accumulated value hold function
- Interval of 2 or 5 minutes can be selected
- Length of lead wire with connector
- 3 m
- Set point range Instantaneous flow
- 20 - 2000 l/min
- Accuracy temperature characteristics
- ±5.0 % F.S. (Ambient temperature of 0 to 50 °C, 25 °C standard)
- Minimum display unit Accumulated flow
- 10 L
- Conform to the European Ro H S Directive
- Conform
- Contact material for circulating fluid
- Stainless steel 304, Aluminium alloy, PPS, HNBR [Sensor: Pt, Au, Ni, Fe, Lead glass (exempted from the RoHS application), Al2O3]
- Smallest settable increment Accumulated flow
- 10 L
- Power supply voltage when used as an I O- Link device
- 21.6 to 30 VDC